Ul assembly book sti

The next generation of the ul white book is here, ul product spec. Floor assembly application throughpenetrantpipe material ul system description ul system number us ul system number canada flat form deck. Please click the specific link below to access the information you are looking for. D t d t a s e t specseal es elastomeric sealant sti firestop. A fireresistance rating refers to the period of time an assembly is able to contain a fire and perform its intended structural function.

Underwriters laboratories of canada ulc is an independent product safety testing, certification and inspection organization. Outlet boxes for use in fire rated assembliescontinued. Your selections will be listed above the result list. Sti is an industry leader solely committed to the development of innovative, reliable firestopping solutions that help stop the. To prevent this, firerated construction joint assemblies are installed at these intersections. Astm e814 and ul 1479 are generally accepted as equivalent by the model code groups. Our wind farm design software enables you to optimize turbine layouts in order to maximize energy production, minimize. Ul is a global independent safety science company offering expertise across three strategic businesses. Ul guide information for category codes qbwy and qcit are also available in the ul white book. Change the testing authority by clicking on the top left button.

Ul standards list ul standards directories ul product. Use the select system properties sidebar to filter your selections. A secure, online source for increased visibility into your ul project files, product information, documents, samples and services. The sealant prevents the passage of fire through a fireresistive partition or floorceiling assembly. Only products which bear ul s mark are considered certified. The ul certification mark on fire resistant products, systems and assemblies is relied on by code enforcement officials and buyers to provide confidence that products and systems meet regulatory and market requirements. Ul 1479 standard for fire tests of penetration firestops. Find an appropriate firestop system by searching with the system number or by inputting the application characteristics into the filters. Re 101repair of firerelated gypsum board partitions. Ul product spec contains all the ul white book information, and more, for electrical construction materials as well as building and firerelated construction.

Usg fireresistant assemblies catalog english sa100. Quickly access ul certification information with the powerful search engine product iq. Should you experience any issues with installation, please contact your system administrator. Stcrating of 56 when tested in stc 56rated wall assembly 25% dynamic joint movement. These ratings are determined by subjecting an assembly to a. It is a free web compliance tool that works on any internetconnected device and right sizes to your screen, be it a. It was thought that this test would be more severe than actual field conditions in that the fire. The wool batt acts as a backing for the intumescent sealant that is used to seal both ends of the sleeve. Fire resistance assemblies and products are dev eloped b y the design submitter and ha ve been investigated b y ul for compliance with applicable requirements. Results shall be reported be reported in accordance with the performance in the tests prescribed in these test method. Verify that the throughpenetration system being used has been tested to the hourly rating necessary ie. Providing a product to sealup these openings is a natural fit. Scroll to the bottom of the page to see the definitions for each ul rating type.

Ul design u415 1, 2, 3, or 4 hour wall assembly installation instructions ul systems. Ul standards encompass ul s extensive safety research and scientific expertise. The intuitive search tool allows you to quickly locate the product or component that will meet your needs. The guide information includes specifics concerning alternate materials and alternate methods of construction. Throughfirestop system using unique fire stop products membrane firestop. Use the select system properties list to filter your selections. Testing of fire resistive components and assemblies may be conducted by any of several independent testing laboratories. A small scale floor assembly was constructed utilizing a small wall section attached to the underside see fig. Outline of investigation for pump tank extinguishers. See items 3, 4 and 4a unrestrained beam ratings 1, 112, 2 and 3 hr. With over a century of experience in the development of more than 1,500 standards, ul is an accredited standards developer in the us and canada. See items 4, 4a, 7 and 11 supports 8x28 min size steel beams.

Our software provides easytouse tools to collect sustainability metrics, identify trends. Gypsum wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall. Wall assembly the 1 or 2 hr firerated gypsum boardstud wall assembly shall be constructed of the materials and in the manner. See batts and blankets bknv or bzjz categories for names of classified companies. Sti firestop expands architectural design bim resources with bimsmith. Restrained assembly ratings 1, 112, 2 or 3 hr see item 10 unrestrained assembly ratings 34, 1, 112, 2 or 3 hr see item 10. L563 february 26, 2015 unrestrained assembly rating 1 hr. Sti product data sheet es elastomeric sealant fod5032 01 2012. A test first used by ul back about ten years ago utilized a construction thought to simulate the condition. Select a system that matches the application by clicking in the system box. Popf pops 16 bits off the stack into the flags register, which means if will be set or cleared based on the ninth bit on the top of the stack. Standard for surface raceways and fittings for use with data, signal, and control circuits.

See precast concrete units category in the fire resistance directory for names of. The ul fire resistance directories provide details on wall and floor construction as well as hundreds of designs for the protection of throughpenetrations. Floor and ceiling runners not shown channel shaped, fabricated from min 25 msg. Electrical rigid metal conduit aluminum, red brass, and stainless steel. Firestopping wood floor chase assemblies sti firestop. Only products which bear ul s mark are considered as classified, listed, or recognized. The most prominent testing laboratories evaluating fire resistive materials and assemblies are ul and ul of canada. The hourly fire resistance ratings listed are f ratings. Local code approval documents and certificates of conformance for our firestopping products. Wall assembly the 2 hr firerated gypsum boardstud wall assembly shall be constructed of the materials and in the manner described in the individual u400, v400 or w400 series wall or partition designs in the ul fire resistance directory and shall include the following. Ul u356 with thermoply red or blue applied as exterior structural sheathing in onehour rated fire endurance wall assemblies exposed to fire on interior face only for gwb.

Unique fire stop products ul systems ratings ul 1479. If firerated, then a firestop product must be used. Normal weight or lightweight concrete normal weight concrete carbonate or siliceous. The type of product used to seal these openings will depend on the assembly penetrated. Products for life safety and code compliance firestopping.

Our breadth, established objectivity and proven history mean we are a symbol of trust, enabling us to help provide peace of mind to all. The published information cannot alw ays address every construction nuance encountered in the field. This page allows you to search for your desired product or assembly. Newsletters for code authorities ul quarterly newsletters provide code authorities with relevant technical articles and timely updates on ul developments that can enhance your ability to approve safe, sustainable code compliant installations. Fire resistance ratings ansi ul 263 see general information for fire resistance ratings ansi ul 263 design no. Estimate materials and find usg equivalents for your building projects. Click on the i to learn more about the system attributes. Firestop systems tested to astm e814 ul1479 have two ratings.

Ul u356 summary onehour fireresistance rated, limited. To maximize your viewing experience of this digital catalog, we recommend installing adobe flash player plugin. There is a ul classification document for each of our unique fire stop systems applications. Wall assembly configuration a the firerated gypsum boardstud wall assembly shall be constructed of the materials and in the manner specified in the individual u300 or u400 series wall and partition designs in the ul fire resistance directory and shall include the following construction features. The intersection where two firerated assemblies meet for example, a wall assembly and a floorceiling assembly also creates a joint through which fire can spread. Change the result view from list to grid by clicking on icons above. From there, you can view the ul guide information and also all listings under this category. Terms and conditions for usg salesterms and conditions for usg pos. Sti firestopping products for life safety and code. Users of fire resistance assemblies are advised to consult the general guide information for each product category and each group of assemblies. Fireresistance ratings ansiul 263 see general information for fireresistance ratings ansiul 263 design no. These products are already certified for safety by ul before earning the ul energy mark. Inspector pocket guide international firestop council. Occasionally stis engineering services will be asked to comment on what degree of movement is acceptable for a throughpenetration firestop.

Review the selected systems and additional information. U349 september 18, 2012 bearing wall rating 2 hr exposed to fire on interior face only for wood studs, finish rating 55 min. We provide a wide range of publications that include the information you need to provide safe, sustainable code compliant installations. Sti product data sheet ezfirestop grommet fod5129 3356. Find the right firerated assemblies and design details drawings for your architectural plans. Ul design u419 1, 2, 3 or 4 hour wall assembly installation instructions ul systems. After system properties have been chosen, use to add systems to a submittal.

The flag may be set or cleared using the cli clear interrupts, sti set interrupts and popf pop flags instructions. We conduct rigorous independent research and analyze safety data, convene experts worldwide to address risks, share knowledge through safety education and public outreach initiatives, and. Refer to ul system and determine required number of layers. If a nonrated assembly is penetrated, then foam may be utilized. Technical data sheets, sustainability info and productspecific documentation for construction joints, shaft alternative wrap systems, through penetrations, telecom, ul and more. It is a key differentiator for products within the exterior wall assembly market. Ul product iq, formerly known as the online certification directory ocd, has a new look and is easier to use than ever before. Wall may also be constructed of any ul classified concrete blocks. Batts and blankets required as indicated under item 4 mineral wool batts, friction fitted between studs and runners. The interrupt flag if is a system flag bit in the x86 architectures flags register, which determines whether or not the central processing unit cpu will respond to maskable hardware interrupts the bit, which is bit 9 of the flags register, may be set or cleared by programs with sufficient privileges, as usually determined by the operating system.

D916 april 25, 2002 restrained assembly ratings 34, 1, 112, 2 or 3 hr. Astm e814 was developed in the early 1980s to address the need for a test. It is easy for contractors and architects to determine the allowable movement capabilities of a joint system since the test standards, which are either astm e1966 or ul 2079, used to investigate the. The ul energy mark appears on air conditioners and furnaces, refrigerators and freezers, dishwashers, washers and dryers, water heaters, cooking equipment, and similar products evaluated to u. Most people can readily understand this portion of the rating. Access our allnew collection of soundtested, firerated wall assemblies. You can access all current ul fire resistancerated designs using our free product iq tm online search tool, available at product iq is free to use and only requires a simple onetime. These systems should be published and readily available via the internet or other means.

Underwriters laboratories is a nonprofit organization dedicated to advancing the ul mission through the discovery and application of scientific knowledge. The title of the standard used to investigate the product if there is a published ul standard or for international directories an appropriate international or regional standard for the specific product category. See items 1, 6, 7, 8 and 11 unrestrained assembly rating 0 hr. The fcm plugin for autodesk revit uses clash detection to find locations where penetrants meet firerated barriers and automatically selects the appropriate. Title ul design head of wall firestop system page 106 109 85 86 87 re 101 repair of firerated gypsum board partitions sn 103 sn 102 sn 101 sound ratings for 1 hour partitions sound ratings for 2 hour partitions. That term throughpenetrations is the basis for a debate concerning test methods used to evaluate firestop systems for use within what the industry refers to as chase wall. D919 april 25, 2002 restrained assembly ratings 1, 112, 2 and 3 hr see items 1 and 4 unrestrained assembly rating 0 hr see item 3 unrestrained beam rating 1 and 112 hr see item 4 beam w8x28, min size. Usg panels usg panels usg panels ul design number ul design number ul design number g503, g531, l501, l508, n501, n502, n505, p515, p516. Click the reset icon to clear all selections start a new search. Bxuv fire resistance ratings ansiul 263 bxuv7 fire resistance ratings canulcs101 certified for canada see general information for fireresistance ratings ansiul 263 see general information for fire resistance ratings canulcs101 certified for canada design no. Our tools, software solutions and databases help make complex tasks and processes including sustainability, chemical management, health and safety programs, reporting, compliance market access and purchasing decisions easier and more efficient. Covers hourly fire ratings for beams, floors, roofs, columns, walls and. Follow design listing requirements for joints, seams, and overlaps.

131 107 921 331 1450 483 174 1551 1508 960 207 1557 761 1201 606 1515 458 1055 295 1096 502 738 1430 1464 474 624 771 880 595 1386 822 406 855 154 42 610 668 112 1496 528 38 759 1463 1388